With the universal meter YT-73094 with TRUE RMS function and automatic range, basic and advanced electrical measurements can be performed. An additional and convenient option is the capability of non-contact AC voltage detection, as well as phase wire detection by insulation. With the 1.5V and 9V battery test, we can check the voltage of the battery under load. This helps to assess the condition of the battery and rule out or confirm the need for replacement.
Basic measurements:
- AC voltage measurement: A.C. 0-600 V, TRUE RMS + V.F.C.
- DC voltage measurement: DC 0-600 V
- AC current measurement: A.C. 0-10 A, TRUE RMS + V.F.C.
- DC current measurement: DC 0-10 A
- resistance measurement: 0-9,999 MΩ
- diode test:IF 1 mA,UR 3.3 V
- continuity test: 0-30 Ω
Additional measurements:
- capacitor measurement: 0-99.99 mF
- frequency measurement: 0-60 kHz
- non-contact AC voltage detection: NCV
- 1.5 V battery test with a load resistance of approx. 30 Ω
- 9 V battery test with a load resistance of approx. 300 Ω
Measurement accuracies:
Example of accuracy determination for AC voltage measurement. Calculation for measurement result: 235 V
- The measurement accuracy of the YT-73094 meter for this range is: ±(1.2% + 3), resolution 0.1 V
- Calculation of the measurement error formula: (measurement result x 1.2%) + 3 x resolution
- calculation: (235 x 1.2%) + 3 x 0.1 = 2.82 + 0.3 = 3.12 V
Actual result including measurement error for indication 235 V = 235 ± 3.12 V
- Actual result including measurement error for a DC voltage indication 12 V = 12 ± 0.114 V
- actual result including measurement error for the indication of AC current measurement 8 A = 8 ± 0.15 A
A table with the resolution and accuracy for the measurement can be found in the manual.
Built-in functions:
- TRUE RMS - a meter with this function displays the true rms value of the AC voltage/voltage. Unlike averaging meters, devices with true rms display not only the correct value for sine waves, but also for distorted sine waves, for example due to higher harmonics or square or triangular waves. An indispensable function anywhere where switching power supplies, motor inverter drives, HVAC systems, etc. occur in a circuit.
- NCV - non-contact AC voltage detection by inductive method. The meter detects the presence of voltage in an isolated wire and can also indicate the phase wire.
- V.F.C. - low-pass filter. This function is used, for example, when measuring the output voltage of an electric motor controller that uses frequency and voltage variations to control the motor speed (VFD controllers). When the function is activated, the meter filters out high-frequency interference from, for example, a PWM signal and only the low frequency remains. In this way, the filter makes an accurate measurement possible of the rms value of the voltage/current flowing into the motor.
- 1.5 and 9 V battery test - the meter draws a small amount of current from the battery during the test, which gives 100% of the information needed to assess whether a certain power source will be able to power our device. For complete information, it is a good idea to first measure the DC voltage and then compare the result with the value from the battery test. Too high a drop or too low a voltage is a clear signal that the power source must be replaced.
- AUTO - automatic adjustment of the measurement range. In the case of measurements of unknown values with a meter with manual adjustment of the measurement range using the rotary knob, the measurements must be performed sequentially from the largest range to the range that provides the most accurate result - otherwise there is a risk that the instrument will be damaged. With a multimeter with the AUTO function, on the other hand, it is enough to perform one measurement and the meter automatically finds the optimal range. The meter starts by default in AUTO mode
- RANGE - manual change of the measurement range. A convenient function when checking many of the same components with a known value, e.g. a series of resistors. Manually setting the range significantly reduces the time of such measurements.
- SEL - change the measurement mode, e.g. from AC to DC voltage measurement
- DATA HOLD - stores the current measured value on the display
Additional information
- LCD display, maximum displayed result: 9999
- screen backlight and flashlight function
- sound signal in the continuity test for resistance under 30 Ω
- automatic switching from the diode test to the continuity test for resistance under 50 Ω (it is not possible to set the meter only for the diode test)
- Test probes included
- construction with overload protection
- ABS housing + so-called holster, i.e. a rubber cover that protects the meter against mechanical damage
- automatic shutdown of the meter
- battery indicator
- power supply: two 1.5 V (AAA) batteries